Skip to content

WallProbe guides

Klein VDV500-123: Which Tone Generator Goes With the Probe?

WallProbe editorial team · Updated 23 November 2026

Klein specifies the VDV500-063 Toner-Pro for the VDV500-123 Probe-Pro on open-ended, de-energised wiring. Check both model numbers on the instruments. Klein lists the generator separately, so confirm what comes with the offer if you still need both parts.

Test the pair before tracing an unknown run

  1. Use a known, disconnected cable and follow the generator’s instructions. Confirm that the probe detects the tone at the far end.
  2. For the cable you want to trace, establish that the run is de-energised and disconnected from equipment before connecting the generator. Seek qualified help for unidentified wiring that could be live.
  3. Compare adjacent candidates and verify the actual pair at the far end. Tone can be heard on or near a neighbouring cable. Label the run after you confirm the pair.

If your job is verifying Ethernet wiring or diagnosing a link that fails in use, check what the chosen wiring or network tester measures. Tracing only helps you locate the path.

Source: kleintools.com.

View the Klein VDV500-123 Probe-Pro listing in the UK.